Item
|
Date of
Tank
Certification
|
Requirements
|
X
|
| Metal I.D.
Plate |
All |
Permanently
attached to the tank or its supporting structure
on the left or right (can be either depending on
year of construction) side near the front |
|
| Stamping
on I.D. Plate |
All |
The
identification plate must be stamped with either: |
TC331 |
|
| MC331 |
|
| MC330 |
|
| (V) External
Visual Inspection (M1) |
All |
Once
per year (Three years from the last test But
no later than Aug 15, 2003) |
|
| (K) Leakage
Test (M1) |
All |
Once
per year (First test no later than Aug 15, 2003) |
|
| (I) Internal
Visual Inspection (M5) |
All |
Once
every 5 Years (First test no later than Aug 15,
2003 if never performed in accordance to
Standard- contact registered facility who
performed last pressure test - M5 inspection) |
|
| (P) Pressure
Test (M5) |
All |
Once
every 5 Years |
|
Liquid and
Vapour Discharge
Openings Less Than 1 1/4"
NPT |
All |
Must
be equipped with an excess flow valve and a
manually operated external valve (approved ball
valve) |
|
Liquid and
Vapour Discharge
Openings of 1 1/4" NPT |
Before
Oct
1/84 |
Must
be equipped with an excess flow valve and a
manually operated external valve (approved ball
valve) or internal shut-off valve (ISC valve) |
|
Liquid and
Vapour Discharge
Openings 1 1/4" NPT or Larger |
Between
Oct
1/84 and Aug
15/02 |
Must
be equipped with a remotely controlled internal
shut-off valve (ISC valve or FlomaticŪ) |
|
Liquid and
Vapour Line and each
Filling and Discharge Line for Liquid |
New
Unit
After Aug
15/02 |
Must
be equipped with a remotely controlled self-
closing valve (ISC valve or FlomaticŪ with
remote cable control or pheumatic control
shut-down) |
|
| Engine Fuel
Line Not Over 3/4" NPT |
All |
Must
be equipped with an excess flow valve |
|
Tanks 3501 USWGC and Larger
|
All
|
Must
be equipped with two means of
automatic closure installed outside the cab at
the ends of the tank in diagonally opposing
locations |
|
Tanks 3500 USWGC and Less
|
All
|
Must
be equipped with a means of automatic closure
installed outside the cab at one end of the tank,
away from the discharge
connection area |
|